Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 106

106
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
[Pr - 9.15]
Motor Mass
Ultraware Name
General: Mass
Range
1 …2,147,483,647
Units
Kg * 65,536
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.16]
Electrical Cycle Length
Ultraware Name
General: Electrical Cycle
Range
100…10,000
Units
mm * 10
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.17]
Encoder Lines / Meter
Ultraware Name
Feedback: Lines/Meter
Range
4000…10,000,000
Units
Lines
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.18]
Maximum Linear Speed
Ultraware Name
Ratings: Maximum Speed
Range
32…32767
Units
m / s * 256
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.19]
Motor Thermal Protection Enable
Ultraware Name
Thermal: Software Protection
Range
0 = Disabled
1 = Enabled
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.20]
Motor Thermostat
Ultraware Name