Standard Drive Parameters
Appendix A
[Pr - 5.03]
Speed Window
Ultraware Name
Speed Functions: Speed Window
Description
If the speed error < Speed Window for 10 ms and the
Within Speed Window output signal is assigned, then the
Within Speed Window output is turned ON
Range
0…1000
Default
10
Units
Rotary motors: rpm; Linear motors: mm/s
When Enabled
Immediately
Applicable Operating Mode
Follower, Analog Velocity Input, Preset
Modbus Address
[Pr - 5.04]
Up to Speed
Ultraware Name
Speed Functions: Up to Speed
Description
If the motor speed > Up to Speed and the Up to Speed
output signal is assigned, then the Up to Speed output is
turned ON.
Range
1…5000
Default
20
Units
Rotary motors: rpm; Linear motors: mm/s
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address
[Pr - 5.05]
Zero Clamp
Ultraware Name
Speed Functions: Zero Clamp
Description
If the Analog Speed command < Zero Clamp, then the
Analog Speed command is ignored and the Motor Speed
command is set to zero.
Range
0…5000
Default
0
Units
Rotary motors: rpm; Linear motors: mm/s
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address
505