Appendix A

Standard Drive Parameters

[Pr - 5.13]

Analog Output CH1 Selection

Ultraware Name

Analog Output 1: Signal

Range

0…28 (except 15,23,25,26)

Default

0

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

514

[Pr - 5.14]

Analog Output CH2 Selection

Ultraware Name

Analog Output 2: Signal

Range

0…28 (except 15,23,25,26)

Default

1

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

515

[Pr - 5.15]

Analog Output CH1 Scale

Ultraware Name

Analog Output 1: Scale

Range

1 …99,999

Units

Units depend on the channel selected in [Pr - 5.13]

Default

500

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

Pr5-15[Lo] = 516, Pr5-15[Hi] = 517

[Pr - 5.16]

Analog Output CH2 Scale

Ultraware Name

Analog Output 2: Scale

Range

1…99,999

Units

Units depends on the channel selected in [Pr - 5.14]

Default

500

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

Pr5-16[Lo] = 518, Pr5-16[Hi] = 519