47

Part 1 Installation

7.5.2 PNP

Specification

(1) Input

part

External Input Specifications (PNP Specification)

Item

Specification

Input voltage

24 VDC

r10%

Input current

7 mA per circuit

ON/OFF voltage

ON voltage --- 8 VDC max.
OFF voltage --- 19 VDC min.

Insulation method

Photocoupler insulation

External devices

[1] No-voltage contact (minimum load of approx. 5 VDC/1 mA)
[2] Photoelectric/proximity sensor (PNP type)
[3] Sequencer

transistor

output (open-collector type)

[4] Sequencer contact output (minimum load of approx. 5 VDC/1 mA)

[Input circuit]

* N: I/O interface pin No. 17B

Caution

If a non-contact circuit is connected externally, malfunction may result from leakage current.
Use a circuit in which leakage current in a switch-off state does not exceed 1 mA.

~ SSEL controller’s input signal

At the default settings, the system recognizes the ON/OFF durations of input signals if they are
approx. 4 msec or longer. The ON/OFF duration setting values can also be changed using I/O
parameter No. 20 (input filtering frequency).

Internal circuit

Input terminal

External power
supply 24 VDC

10%

N*

560

:

3.3 K

:

ON duration

OFF duration

+

-