beautypg.com

Chapter 2 standard mode, I/o interface list, 311 part 3 positioner mode – IAI America SSEL User Manual

Page 333

background image

311

Part 3 Positioner Mode

Chapter 2 Standard Mode

The standard mode provides a PIO pattern of greatest general utility among all positioner modes
accessible in the SSEL controller.

1. I/O Interface List

Pin

No.

Category

Port

No.

Signal name

Signal

symbol

Function overview

Cable

color

1A

P24

External power supply 24 V

P24

1-Brown

1B

016 Position input 10

PC10

1-Red

2A

017 Position input 11

PC11

1-Orange

2B

018 Position input 12

PC12

1-Yellow

3A

019 Position input 13

PC13

(Same as position inputs 1 through 9)

1-Green

3B

020 Position input 14

PC14

1-Blue

4A

021 Position input 15

PC15

1-Purple

4B

022 Position input 16

PC16

1-Gray

5A 023

Error reset

RES

Present alarms will be reset at the leading edge of this
signal.

1-White

5B 000

Start

CSTR

The actuator will start moving at the leading edge of this
signal.

1-Black

6A 001

Home

return HOME

The actuator will start home-return operation at the leading
edge of this signal.

2-Brown

6B 002

Servo

ON

SON

The servo will remain on while this signal is ON, and remain
off while this signal is OFF.

2-Red

7A 003

Push

motion PUSH

The actuator will start linear interpolation operation if the
start input signal is turned ON while this signal is ON.

2-Orange

7B 004

*Pause

*STP

The actuator can be moved when this signal is ON, and will
decelerate to a stop when the signal turns OFF.

2-Yellow

8A 005

*Cancellation *CANC

The remaining travel distance will be cancelled if this signal
turns ON.

2-Green

8B 006

Interpolation LINE

With the 2-axis specification, linear interpolation operation
will start when the start input signal is turned ON while this
signal is ON.

2-Blue

9A

007 Position input 1

PC1

2-Purple

9B

008 Position input 2

PC2

2-Gray

10A

009 Position input 3

PC3

2-White

10B

010 Position input 4

PC4

2-Black

11A

011 Position input 5

PC5

3-Brown

11B

012 Position input 6

PC6

3-Red

12A

013 Position input 7

PC7

3-Orange

12B

014 Position input 8

PC8

3-Yellow

13A

Input

015 Position input 9

PC9

Input the position number corresponding to the position you
want to move the actuator to.
Be sure to specify a position input by no later than 6 msec
before the start input signal turns ON.
Position numbers are input as binary codes (factory setting).
The input mode can be changed to BCD by changing the
setting of other parameter No. 71.
(PC1 through 4 indicate the one’s place, PC5 through 8
indicate ten’s place, PC9 through 12 indicate the hundred’s
place, and PC13 indicates the thousand’s place.)

3-Green

13B 300

*Alarm

*ALM

This signal remains ON if the controller is normal. It will turn
OFF if an alarm occurs.

3-Blue

14A 301

Ready

RDY

This signal will turn ON when the controller becomes ready.

3-Purple

14B 302

Positioning

complete

PEND

This signal will turn ON once the actuator has moved to the
target position and entered the positioning band.

3-Gray

15A

303 Home return complete

HEND

This signal is OFF when the power is input, and will turn ON
when home return is completed.

3-White

15B

304 Servo ON output

SVON

This signal will turn ON when the servo is turned on, and
turn OFF when the servo is turned off.

3-Black

16A 305

Push motion

complete

PSED

This signal will turn ON when the push-motion operation is
completed successfully, and turn OFF if the work is mixed.

4-Brown

16B

306 System battery error

SSER

This signal will turn ON when the voltage of the system-
memory backup battery drops to the voltage-low warning
level.

4-Red

17A

Output

307 Absolute battery error

ABER

This signal will turn ON when the voltage of the absolute-
data backup battery drops to the voltage-low warning level.

4-Orange

17B

N

External power supply 0 V

N

4-Yellow

*: Contact B (always ON)