Troubleshooting of ssel controller – IAI America SSEL User Manual

Page 488

background image

466

Appendix

~ Troubleshooting of SSEL Controller

The X-SEL controller has a panel window on its front side.
This panel window displays an error number every time an error generates.
When the power is turned on, normally “rdy” or “Ardy” will be displayed. “P01” or other code will be displayed
while a program is running.
When an error generates, the panel window will show “EA1D” or other code starting with “E.” (Some errors do
not begin with “E.”)

Status

Panel window display

After turning on the power

rdy, Ardy

Program is running

P01, P64, etc.

Error has generated

EA1D, ED03, etc.

* Among the alphabets, B and D are shown in lower case.

Depending on the error number, it may be possible to reset the error after removing the cause of the error, or
the power must be reconnected to reset the error.
Also, some error numbers are output to the LED display in the panel window, while others are not.
For details, see “

~ Error Level Control.”