(2) Explanation of input function specification values

Input function specification value 0: General-purpose

input

The applicable input can be used freely in programs as a general-
purpose input.

Input function specification value 1:

Program start signal (BCD) (ON edge)

The applicable signal is set as a program start signal.

Once set, the signal can start the BCD program number specified
by input function setting values 9 through 15.

Input function specification value 2:

Program start signal (BIN) (ON edge)

The applicable signal is set as a program start signal.

Once set, the signal can start the binary program number specified
by input function setting values 9 through 15.

Input function specification value 3:

Soft reset signal (ON edge)

Allow the applicable signal to restart the controller in the event of an
error, etc.

Note 1: The input signal must remain ON for at least 1 second.

Note 2: The coordinate values will be cleared, so home return

must be performed again.

Input function specification value 4:

Servo ON

Allow the applicable signal to turn on the servo of a valid axis at its
ON edge.

The signal will turn off the servo of a valid axis at its OFF edge.

Note:

There must be an interval of at least 1.5 seconds between
ON and OFF edges.

Input function specification value 5:

Auto-start program start signal

If an auto-start program is set, this signal can be used to start the
program.

The program will start at the ON edge of this signal, while all
operations and programs will be aborted at the OFF edge.

Input function specification value 6:

Soft interlock for all servo axes (OFF level)

The active programs will be paused and all servos will turn off when
this signal turns OFF.

(Any moving axis will decelerate to a stop first, after which its servo
will turn OFF.)

Input function specification value 7:

Operation-pause reset signal (ON edge)

Allow the applicable signal to reset the operation pause signal set
by input function selection value 8.

Input function specification value 8:

Operation pause signal (OFF level)

Allow the applicable signal to pause all valid axes.

Note:

The pause will be reset at the ON edge of the operation-
pause reset signal (specified by input function selection 7)
after turning this signal ON.