IAI America SSEL User Manual
Page 448
426
Appendix
Other Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
49 Panel
7-segment
display data type
0
0 ~ 9
0: Display controller status
1: Display motor current indicator
The current pattern of each axis is displayed instead of
“ready status” or “program run number.”
“Minimum indicator-displayed axis number” (far-right
column) is specified by “Other parameter No. 50.”
0 < Motor current to rating ratio (%)
d 25
25 < Motor current to rating ratio (%)
d 50
50 < Motor current to rating ratio (%)
d 75
75 < Motor current to rating ratio (%)
d 100
100 < Motor current to rating ratio (%)
d 150
150 < Motor current to rating ratio (%)
d 200
200 < Motor current to rating ratio (%)
2: Display user information number (U001 to U999)
The user information number is displayed instead of “ready
status” or “program run number” only when the user
information number is not “0.” “Global integer variable
number for specifying user information number” is specified
by “Other parameter No. 50.”
50 Auxiliary
specification
for panel 7-segment
display data type
0 -99999999
~
99999999
* Refer to the Remarks field for “Other parameter No. 49.”
51 ~
70
(For expansion)
0
71 Positioner
mode
parameter 1
0 -99999999
~
99999999
72 Positioner
mode
parameter 2
0 -99999999
~
99999999
73 Positioner
mode
parameter 3
0 -99999999
~
99999999
74 Positioner
mode
parameter 4
0 -99999999
~
99999999
75 Positioner
mode
parameter 5
0 -99999999
~
99999999
76 ~
100
(For expansion)
0