beautypg.com

416 appendix axis-specific parameters – IAI America SSEL User Manual

Page 438

background image

416

Appendix

Axis-Specific Parameters

No Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

105 Effective

multi-slider

stroke

0 0

~

99999999

0.001 mm

Set “[Distance between sliders at the farthest positions
allowed] – [Distance between sliders at the closest positions
allowed]” when both of the sliders subject to multi-slider
near-miss detection are inside the range of operation.
(Only the parameter for the main multi-slider axis is
effective.)
(Main application version 0.12 or later)

106 Emergency

deceleration

pattern at multi-slider
near-miss

5

0 ~ 999

0.01 G

(Main application version 0.12 or later)

107 Multi-slider

setting:

Bit

pattern 1

12H OH

~

FFFFFFFFH

Bits 0 to 3: Multi-slider actual position near-miss detection

margin (mm)
(Only the parameter for the main multi-slider
axis is effective.)
(Main application version 0.12 or later)

Bits 4 to 7: Multi-slider command position near-miss

detection margin (mm)
(Only the parameter for the main multi-slider
axis is effective.)
(Main application version 0.12 or later)

108 ~

118

(For extension)

0

~

119 FSG

0

0

~

100

120

FFF

10

0 ~ 100

* Change is prohibited unless instructed by the manufacturer.

121~

200

(For expansion)

0

~