Appendix

7. Other

Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1 Auto-start

program

number

0

0 ~ 128

(Invalid if “0” is set)

2 I/O

processing

program number at
operation/program
abort

0

0 ~ 128

The start trigger is determined from the “I/O processing
program start type at operation/program abort.” (Note: This
program will be started before confirming an abort of other
programs.)
(Invalid if “0” is set) * If the setting is valid, the number of
user program tasks that can be used will decrease by 1.

3 I/O

processing

program number at all
operation pause

0

0 ~ 128

This program will be started when an all-operation-pause
command is issued due to an all-operation-pause factor.
(Only when a program is running) (Invalid if “0” is set) * If
the setting is valid, the number of user program tasks that
can be used will decrease by 1.

4

Program abort type at
error

0

0 ~ 5

0: Cancel only the program in which an error of operation-

cancellation level or higher has generated. (If the error
requires the drive source to be cut off or a servo-OFF or
all-axis servo-OFF request to be issued, all programs
other than the “I/O processing program at
operation/program abort” will be cancelled.)

1: Cancel all programs other than the “I/O processing

program at operation/program abort” when an error of
operation-cancellation level or higher has generated.

5 I/O

processing

program start type at
operation/program
abort

0

0 ~ 5

0: When all-operation-cancellation factor has generated

(Only when a program is running)

1: When all-operation-cancellation factor has generated

(Always)

2: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4 = 0”
is considered) (Only when a program is running)

3: All-operation-cancellation factor + Error of operation-

cancellation level or higher (“Other parameter No. 4 = 0”
is considered) (Always)

6 PC/TP

reconnection

delay at software reset

14000

1 ~ 99999

msec

* The setting will become effective after the controller, PC

or TP is restarted.

7

Auto program start
setting

0

0 ~ 5

0: Do not start the auto-start program upon power ON

reset/software reset

1: Start the auto-start program

8 (For

expansion)

0

9

For future expansion
(change prohibited)

0

0 ~ 2

10 Emergency-stop

recovery type

0

0 ~ 4

0: Abort operations/programs
1: Recovery after reset
2: Operation continued (Only during automatic operation.

* Operation commands from the PC/TP will be aborted

on the PC/TP side.)

3: Abort operations/programs (Software reset when the

emergency stop is reset. The home-return completion
status of incremental-encoder axes will be reset (EG
approximation swap).)

4: Abort operations/programs (Error reset (only with an

error of operation-cancellation level or lower) and auto-
start program start (only if AUTO mode AND other
parameter No. 7 = 1 AND I/O parameter “Input function
selection”

z 17 AND all-operation-cancellation factor is

not present) when the emergency stop is reset.

There must be a minimum interval of 1 second after an
emergency stop is actuated before it is reset. The
home-return completion status of incremental-encoder
axes will be retained.

11 Enable

switch

(deadman/enable
switch) recovery type

0

0 ~ 2

0: Abort operations/programs
1: Recovery after reset
2: Operation continued (Only during automatic operation.

* Operation commands from the PC/TP will be aborted

on the PC/TP side.)