322

Part 3 Positioner Mode

3.

Details of Each Input Signal

Start (CSTR)

Movement to the position corresponding to the position data of the specified product will start upon
detection of the OFF

ON leading edge of this signal. Product numbers and position numbers are

specified by the 16-bit binary code consisting of inputs 1 through 16.
Before movement is started, the target position, speed and acceleration/deceleration must be set as
position data. Use a PC (software) or teaching pendant to set position data.
If this signal is input when no single home-return operation has been performed after the power was input
(= when the HEND output signal is OFF), “C6F, Home-return incomplete error” will generate.

Inputs 1 through 16 (PC1 through 16) : Controller Capable for Memory Capacity Increase

Sixteen bits of inputs 1 through 16 are divided into position-number input bits and product-number input
bits.
Example)

Assume that the parameters are set as follows:

Other parameter No. 71 = 0 (Binary) “Position-number input mode specification”
Other parameter No. 72 = 6 “Number of position-number input bits”
Other parameter No. 73 = 400 “Number of positions per product”

Each position number input is assigned to six bits of inputs 1 through 6 (007 through 012), as a binary
code.
Each product number input is assigned to 10 bits of inputs 7 through 16 (013 through 022), as a binary
code.
Position numbers and product numbers are specified as shown in the table below, based on the ON/OFF
levels of inputs 1 through 16. (Example for Item 1 to 4)

t

u

p

n

i

r

e

b

m

u

n

n

o

i

t

i

s

o

P

t

c

u

d

o

r

P

Product 1 Product 2 Product 3 Product 4

Input 6

Input 5

Input 4

Input 3

Input 2

Input 1

1

51

101

151

0

0

0

0

0

0

2

52

102

152

0

0

0

0

0

0

3

53

103

153

0

0

0

0

0

0

4

54

104

154

0

0

0

0

0

0

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

49

59

149

199

1

1

0

0

0

1

Position number

(when set)

50

100

150

200

1

1

0

0

1

0

Input

7

1

0

1

0

Input

8

0

1

1

0

Input

9

0

0

0

1

Input

10

0

0

0

0

Input

11

0

0

0

0

Input

12

0

0

0

0

Input

13

0

0

0

0

Input

14

0

0

0

0

Input

15

0

0

0

0

Product numbe

r input

Input

16

0

0

0

0

Fifty position numbers (Nos. 1 through 400) can be specified for each product.
Position No. 49 for product 2 (set as No. 99 within the entire data) is specified as follows.

Input 16

Input 15

Input 14

Input 13

Input 12

Input 11

Input 10

Input 9

Input 8

Input 7

Input 6

Input 5

Input 4

Input 3

Input 2

Input 1

0

0

0

0

0

0

0

0

1

0

1

1

0

0

0

1