IAI America SSEL User Manual
Page 197
175
Part 2 Programs
z MOVP (Move PTP by specifying position data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
MOVP
Position
number
Prohibited PE
[Function] Move the actuator to the position corresponding to the position number specified in operand
1, without interpolation (PTP stands for “Point-to-Point”).
The output will turn OFF at the start of axis movement, and turn ON when the movement is
complete.
[Example 1]
VEL
100
Set the speed to 100 mm/s.
MOVP
1
Move the axes to the position corresponding to position No.
1 (200, 100).
[Example 2]
VEL
100
Set the speed to 100 mm/s.
LET
1
2
Assign 2 to variable 1.
MOVP
*1
Move the axes to the position corresponding to the content
of variable 1 (position No. 2, or (100, 100)).
Position Data Display in PC Software
No. Axis
1
(X-axis)
Axis 2
(Y-axis)
Vel Acc Dcl
1 200.000 100.000
2 100.000 100.000
(Note) If acceleration and deceleration are not specified by position data or ACC (DCL) commands,
the actuator operates at the default values set in all-axis parameter No. 11, “Default
acceleration” and all-axis parameter No. 12, “Default deceleration.”
Travel path from the home to the position corresponding to position No. 1 (200, 100)
X-axis
Y-axis
Only the Y-axis completes
movement.
Each axis moves at
100 mm/s.
Home 0
100 mm
100 mm
200 mm