I/o parameters, 1 i/o parameters – IAI America SSEL User Manual
Page 424
402
Appendix
1. I/O
Parameters
1.1 I/O
Parameters
No. Parameter
name
Default
value
(Reference)
Input range
Unit
Remarks
1
I/O port assignment type
1
0 ~ 20
0: Fixed assignment
2
Input port start number
with fixed standard I/O
assignments (I/O1)
000
-1 ~ 599
0 + (Multiple of 8) (Invalid if a negative value is set)
3
Output port start number
with fixed standard I/O
assignments (I/O1)
300
-1 ~ 599
300 + (Multiple of 8) (Invalid if a negative value is set)
4 ~ 9 For future expansion
-1
-1 ~ 599
10
Standard I/O error
monitor
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O
power source)
3: Monitor (Monitor only errors relating to 24-V I/O power
source)
* Some exceptions apply.
* If this parameter is set to “0” (= Do not monitor) or “2” (=
Do not monitor errors relating to 24-V I/O power
source), a system error will not generate even when the
24-V I/O power source presents abnormality. However,
the actual outputs from digital I/Os will be cut off by
circuitry thereafter to protect the controller.
11 ~
13
For future expansion
1
0 ~ 5
14 Network
system
reservation
0
0 ~ 256
15 Network
system
reservation
0
0 ~ 256
16 Network
system
reservation
-1
-1 ~ 599
17 Network
system
reservation
-1
-1 ~ 599
18 Network
system
reservation
1
0 ~ 5
19 (For
expansion)
0
20
Input filtering periods
2
1 ~ 9
msec Input signal is recognized when the status is held for twice
the period set by this parameter.
21
For future expansion
(change prohibited)
0
1 ~ 9
22
For future expansion
0
0 ~ 99999
msec
23
For future expansion
0H
0H ~
FFFFFFFFH
24
I/O setting bit pattern 1
10000H
0H ~
FFFFFFFFH
Bits 0 to 3: RDY OUT function selection (System IO)
(0: SYSRDY (Software = PIO trigger program
can be run) and hardware is normal
(emergency stop has not been actuated
and hardware error is not present)
1: Error of operation-cancellation level or
higher is not present
2: Error of cold-start level or higher is not
present)
Bits 4 to 7: RDY LED function selection
(0: Program can be run
1: Error of operation-cancellation level or
higher is not present
2: Error of cold-start level or higher is not
present)
Bits 8 to 19: For future expansion
25
I/O setting bit pattern 2
0H
0H ~
FFFFFFFFH
26 (For
expansion)
0
27 (For
expansion)
0
28 (For
expansion)
0