IAI America SSEL User Manual
Page 419
397
Appendix
Description
Action
Parameter
settin
g
Operation/outco
me
15
Output a signal
w
h
en all valid
axes have completed home
return.
A desired output
port can be set
as an all-valid-axes home-ret
urn
complete output.
Set the follow
ing
value in the I/O p
aramete
r “Output
function selectio
n n” corresponding to the selected input
port:
I/O pa
rameter “Output function specification va
lue” = 13
The specified port w
ill turn
ON
when all
valid axes have completed home return.
16
Output a
warning
signal w
hen
the voltage of the
sy
stem
-
memory backup
battery became
low
.
A desired output
port can be set
as a voltage-low
w
a
rning outp
ut
for the s
y
stem
-m
emory
backup
battery.
Set the follow
ing
value in the I/O p
aramete
r “Output
function selectio
n n” corresponding to the selected input
port:
I/O pa
rameter “Output function specification va
lue” = 15
The specified port w
ill turn
ON
when the
voltage of the s
y
stem-memory ba
ckup
battery became l
ow
.
17
Output a
warning
signal w
hen
the voltage of the
absolute
encoder batte
ry
became low
.
A desired output
port can be set
as a voltage-low
w
a
rning outp
ut
for the absolute
encoder batte
ry.
Set the follow
ing
value in the I/O p
aramete
r “Output
function selectio
n n” corresponding to the selected input
port:
I/O pa
rameter “Output function specification va
lue” = 16
The specified port w
ill turn
ON
when the
voltage of the ab
solute encoder b
a
ttery
became low
.
18
Release the brak
e using an
external input signal.
A desired input p
o
rt can be set as
a forced brake
-re
lease input.
Set the follow
ing
value in each I/O paramete
r “Inp
ut
function selectio
n n” corresponding to the selected input
port:
I/O pa
rameter “In
put function specification value” =
22
(Axis 1)
I/O pa
rameter “In
put function specification value” =
23
(Axis 2)
Setting example) To set input port
No. 12 as the b
rake
release input for
axis 2, set “23” in
I/O pa
ramete
r N
o.
42.
The brake
w
ill be forcibly
released w
h
en
the specified port turns ON
.
19
Retain output co
nditions upon
actuation of an e
m
ergenc
y
stop
or opening of t
he
safet
y
gate.
The minimum an
d maximum
output port
numb
ers can be set to
specify
a
range o
f outputs
w
hose
condition is to be retained.
I/O pa
rameter N
o. 70 = Min. outp
ut port num
ber
I/O pa
rameter N
o. 71 = Max.
out
put port nu
mber
Setting example) To retain th
e conditions of output
port
Nos. 303 thro
ugh
307, set as follow
s:
I/O pa
rameter N
o. 70 = 303
I/O pa
rameter N
o. 71 = 307
m
The con
ditions of output port
N
o
s.
303 throu
gh 307
w
ill be retained
w
hen
the emerge
nc
y
st
op input turns
ON or
the safet
y
gat
e o
pens.
20
Start a program
w
h
en the
emergenc
y stop input turns
ON
or the safet
y gat
e opens.
Programs that ca
n be started in
these conditions are limited to
those not contain
ing I/O
processing, calculation
processing or an
y othe
r
processing involving actuator
operation (PI
O p
rocessing
programs
).
A PIO processing program to be
started in these conditions can be
set. The pro
gram
number of t
he
applicable PIO processing
program
, and the
minimum and
maximum outpu
t
port numbe
rs
indicating the range of processed
outputs, are set
b
y
pa
ramete
rs.
Other
param
eter
No. 2 = PIO p
roc
essing program
number
Other
param
eter
No. 70 = Min. out
put port nu
mber
Other
param
eter
No. 71 = Ma
x. ou
tput port n
umber
Setting example) To start p
rogram
No. 5 that p
roce
sses
output port
Nos.
303 throu
gh 307,
set as follow
s:
Other
param
eter
No. 2 = 5
Other
param
eter
No. 70 = 303
Other
param
eter
No. 71 = 307
m
Program No.
5 w
ill start
w
hen the
emergenc
y stop input turns
ON o
r
the
safet
y
gate o
pen
s.
Output p
ort N
os. 303 throu
gh 307
can
be processed.