IAI America SSEL User Manual
Page 445
423
Appendix
Other Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
12 Automatic
operation
recognition type
0
0 ~ 3
0: Program is running AND all-operation-cancellation factor is
not present
1: [Program is running OR in AUTO mode] AND all-operation-
cancellation factor is not present
13 ~
19
(For expansion)
0
20 System-memory
backup battery
installation function
type
0
0 ~ 2
0: Not installed (SEL global data/error lists cannot be recovered
from the flash ROM)
1: Not installed (SEL global data/error lists can be recovered
from the flash ROM)
2: Installed
* When the power is turned on without battery installed,
point data can be copied from the flash ROM. * Use of
setting “1” will be prohibited for the time being due to
limitations. * When point data is lost due to a battery error,
the point data valid before the flash ROM was written can
be restored
o Input “0” (not installed) and transfer the
setting to the controller, and then perform a software reset
without writing the flash ROM. The point data last written
to the flash ROM will be restored. Thereafter, reset this
parameter to the original value. (No remedy is available for
recovery of SEL global data/error lists.)
21
Manual mode type
0
0 ~ 5
0: Always enable edit and SIO/PIO start (Initial condition after
connection = With safety speed)
1: Select edit and start (with password) (EU, etc.)
2: Always enable edit and SIO/PIO start (Initial condition after
connection = Without safety speed (cancellation))
* Referenced by the PC/TP.
22
Control use region
0
0 ~ 99
0: J, 1: E, 2: EU
23 PSIZ
command
function type
0
0 ~ 5
0: Maximum number of point data areas
1: Number of point data used
24
Local variable number
for storing SEL
communication
command return code
99
1 ~ 99
1001 ~ 1099
25
Operation mode type
0
0 ~ 16
0: Program mode
1 to 16: Positioner mode
26 ~
29
(For expansion)
0
30
Option Password 00
0H
0H ~
FFFFFFFFH
HOME command option (Change prohibited)
* Change is prohibited unless instructed by the manufacturer.
31
Option Password 01
0H
0H ~
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the manufacturer.
32
Option Password 02
0H
0H ~
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the manufacturer.
33 ~
35
(For expansion)
0
0H ~
FFFFFFFFH