4. Noise Control Measures and Grounding

(1) Wiring and power supply

The PE terminal on the power-supply terminal block is used for protective grounding. Provide class D
grounding. The grounding wire should have a size of 1.0 mm

2

(AWG17) or larger and at least a size for AC

power wiring.

[1] Notes on wiring method

Do not twist the lines from the AC power supply and the 24-VDC external power supply. Wire the controller
cables separately from lines creating a strong electric field such as power circuit lines (by not bundling them
together or placing them in the same cable duct).

If you wish to extend the motor cable or encoder cable beyond the length of each supplied cable, please
contact IAI’s Technical Service Section or Sales Engineering Section.

(2) Grounding for noise elimination

Provide dedicated grounding.

Metal enclosure

Other

equipment

Class D grounding

(protective

grounding)

Class D grounding

SSEL

controller

SSEL

controller

Other

equipment

Do not use this method.