17. Canceling the Operation 2 (STOP)

Description

Decelerate the moving axis to a stop and cancel the remaining operation. (STOP)

How to Use

Execute a STOP command from other program to forcibly stop the operation (in the multi-tasking mode).
Specify the axis you want to stop using an axis pattern.

Example of Use 1

STOP command
Main program

Stop control program

If “STOP 11” is executed while “MOVL 1” is being executed, “MOVL 1” will be cancelled and the actuator
will continue its operation from “MOVL 2.”

Example of Use 2

Main program

Stop control program

If “STOP 10” is executed while “MOVL 1” is being executed, only the axis 2 part of “MOVL 1” will be
cancelled. Both axes 1 and 2 will operate under “MOVL 2.”

Caution

If a STOP command is executed during a CP operation (interpolation operation) initiated by MOVL, etc.,
the operations of all axes will be cancelled regardless of the axis pattern specified in the STOP command.

Speed

Input port 15 ON

Remaining

operation

Time

The operation within this range
is cancelled.

The stop program starts.

Wait for stop input.
Axes 1 and 2 stop.

The stop program starts.

Wait for stop input.
Axis 2 stops.