beautypg.com

Chapter 3 product switching mode, I/o interface list, 320 part 3 positioner mode – IAI America SSEL User Manual

Page 342: Same as inputs 1 through 9)

background image

320

Part 3 Positioner Mode

Chapter 3 Product Switching Mode

In addition to position numbers, product numbers can also be specified in this mode. Sixteen bits of inputs
1 through 16 are divided into position number inputs and product number inputs.
In other words, the actuator can be moved to different positions for different products by specifying the
same position number.

1. I/O Interface List

Pin

No.

Category

Port

No.

Signal name

Signal

symbol

Function overview

Cable

color

1A

P24

External power supply 24 V

P24

1-Brown

1B 016

Input

10

PC10

1-Red

2A 017

Input

11

PC11

1-Orange

2B 018

Input

12

PC12

1-Yellow

3A 019

Input

13

PC13

1-Green

3B 020

Input

14

PC14

1-Blue

4A 021

Input

15

PC15

1-Purple

4B 022

Input

16

PC16

(Same as inputs 1 through 9)

1-Gray

5A 023

Error reset

RES

Present alarms will be reset at the leading edge of this
signal.

1-White

5B 000

Start

CSTR

The actuator will start moving at the leading edge of this
signal.

1-Black

6A 001

Home

return HOME

The actuator will start home-return operation at the leading
edge of this signal.

2-Brown

6B 002

Servo

ON

SON

The servo will remain on while this signal is ON, and remain
off while this signal is OFF.

2-Red

7A 003

Push

motion PUSH

The actuator will start linear interpolation operation if the
start input signal is turned ON while this signal is ON.

2-Orange

7B 004

Pause

*STP

The actuator can be moved when this signal is ON, and will
decelerate to a stop when the signal turns OFF.

2-Yellow

8A 005

Cancellation CANC

The remaining travel distance will be cancelled if this signal
turns ON.

2-Green

8B 006

Interpolation LINE

With the 2-axis specification, linear interpolation operation
will start when the start input signal is turned ON while this
signal is ON.

2-Blue

9A 007

Input

1

PC1

2-Purple

9B 008

Input

2

PC2

2-Gray

10A 009

Input

3

PC3

2-White

10B 010

Input

4

PC4

2-Black

11A 011

Input

5

PC5

3-Brown

11B 012

Input

6

PC6

3-Red

12A 013

Input

7

PC7

3-Orange

12B 014

Input

8

PC8

3-Yellow

13A

Input

015 Input

9

PC9

These input signals specify position numbers and product
numbers.
Sixteen bits of inputs 1 through 16 are divided into position
number inputs and product number inputs. Be sure to
specify an input by no later than 6 msec before the start
signal turns ON.
Position numbers and product numbers are input as binary
codes (factory setting).
The input mode can be changed to BCD by changing the
setting of other parameter No. 71.

3-Green

13B 300

Alarm

*ALM

This signal remains ON if the controller is normal. It will turn
OFF if an alarm occurs.

3-Blue

14A 301

Ready

RDY

This signal will turn ON when the controller becomes ready.

3-Purple

14B 302

Positioning

complete

PEND

This signal will turn ON once the actuator has moved to the
target position and entered the positioning band.

3-Gray

15A

303 Home return complete

HEND

This signal is OFF when the power is input, and will turn ON
when home return is completed.

3-White

15B

304 Servo ON output

SVON

This signal will turn ON when the servo is turned on, and
turn OFF when the servo is turned off.

3-Black

16A 305

Push motion

complete

PSED

This signal will turn ON when the push-motion operation is
completed successfully, and turn OFF if the work is mixed.

4-Brown

16B

306 System battery error

SSER

This signal will turn ON when the voltage of the system-
memory backup battery drops to the voltage-low warning
level.

4-Red

17A

Output

307 Absolute battery error

ABER

This signal will turn ON when the voltage of the absolute-
data backup battery drops to the voltage-low warning level.

4-Orange

17B

N

External power supply 0 V

N

4-Yellow

*: Contact B (always ON)