beautypg.com

Installation environment – IAI America SSEL User Manual

Page 48

background image

26

Part 1 Installation

2. Installation

Environment

(1) When installing and wiring the controller, do not block the ventilation holes provided for cooling. (Insufficient

ventilation will not only prevent the product from functioning fully, but it may also result in failure.)

(2) Prevent foreign matter from entering the controller through the ventilation holes. Since the controller is not

designed as dustproof or waterproof (oilproof), avoid using it in a dusty place or place subject to oil mist or
splashed cutting fluid.

(3) Do not expose the controller to direct sunlight or radiant heat from a high heat source such as a heat-

treating furnace.

(4) Use the controller in a non-condensing environment free from corrosive or inflammable gases.
(5) Use the controller in an environment where it will not receive external vibration or impact.
(6) Prevent electrical noise from entering the controller or its cables.

Environmental Condition of Controller

Item Specification

and

description

Surrounding air temperature

range

0 ~ 40

qC

Surrounding humidity range

10% ~ 95% (Non-condensing; conforming to JIS C3502 RH-2)

Storage temperature range

-25

qC ~ 70qC (Excluding the battery)

Maximum operating altitude

2000 m

Protection class

IP20

Vibration

10

d f < 57: 0.035 mm (continuous), 0.075 mm (intermittent)

57

d f d 150: 4.9 m/s

2

(continuous), 9.8 m/s

2

(intermittent)

X, Y and Z directions

Impact 147

mm/s

2

, 11 ms, half-sine pulse, 3 times each in X, Y and Z directions