IAI America SSEL User Manual
Page 464
442
Appendix
(In the panel
wind
ow, the three di
gits after “E” in
dicate an error n
u
m
ber.)
Error No.
Error name
Description, ac
tion, etc.
A40
Data change refusal err
or dur
ing flas
h ROM w
rit
e
Data
cannot be changed
w
h
ile
the flash ROM is being
w
ritten.
A41
Duplicate flas
h-ROM
w
rite commands refus
al error
Another flas
h-
ROM
w
rite command
w
a
s received
w
h
ile the flash ROM
w
a
s bei
ng
w
ritten.
A42
Direct monit
or prohibiti
on err
or durin
g
flash R
O
M
w
rite
Direct monit
or i
s
prohi
bited
w
h
ile the flas
h R
O
M is being
w
ritten.
A43
P0/P3-area dir
ect monitor prohibition err
or
Direct monit
or in the P0/P3 ar
eas is prohibited.
A44
Point-data count specification error
T
he
specified number of point
data is inv
ali
d.
A45
S
y
mbol-rec
ord
count spec
ification error
T
he
specified number of s
y
mbol recor
ds is invalid.
A46
Variable-
data c
ount spec
ificati
on error
T
he specified n
u
mber of vari
a
b
le d
a
ta is inv
a
lid.
A48
Error-detail quer
y
t
y
pe 1 error
Error-detail quer
y
t
y
pe 1 is invalid.
A49
Error-detail quer
y
t
y
pe 2 error
Error-detail quer
y
t
y
pe 2 is invalid.
A4A
Monitori
ng data t
y
pe error
T
he data type f
o
r monitor
ing data quer
y is i
n
v
a
lid.
A4B
Monitori
ng-r
ec
ord count speci
fication err
or
T
he specified number of recor
ds for monitori
ng data
quer
y i
s
invali
d.
A4C
Monitori
ng-
operation special command regist
er bus
y error
T
he driver spe
cial comma
nd
ACK gen
erate
d a timeout d
u
ri
ng mo
nitori
ng oper
ation.
A4E
Parameter regi
ster bus
y
error
at issuanc
e of slave comm
and
T
he
driver special command
ACK generated a timeout at i
ssuanc
e o
f a slave
command.
A4F
Soft
w
a
re reset
refusal err
or during operati
on
Soft
w
a
re reset
(SIO) is prohibi
ted dur
ing oper
ation (pr
ogram
is running, serv
o is in
use, etc.).
A50
Drive-source r
e
cover
y
request refusal error
T
he drive-source
cutoff factor (error, deadm
an s
w
itch, safet
y
gate, emer
genc
y s
top,
etc.) has not been rem
oved.
A51
Operation-pause reset request refusal
error
T
he all-oper
ati
on-pause factor (drive-sourc
e
cutoff, operation-pause signal, de
adm
an
s
w
itc
h, safet
y
gate, emergenc
y
st
op, etc.) has not been removed.
A53
Refusal error due to servo ON
A processing not permitted during serv
o ON w
a
s attempted.
A54
Refusal error due to uns
uppor
ted func
tio
n
T
he function is not supp
orted.
A55
Refusal error due to ex
clus
ive manufacturer f
unction
A processi
ng not opened to users other than the manufacturer
w
a
s attem
pted.
A56
Refusal error due to invali
d data
T
he data is invalid.
A57
Program start duplication err
or
An attempt
w
a
s made to start a program cur
rently
r
u
nning.
A58
BCD error
w
a
rn
ing
T
he BCD value
being read may be inva
lid, or
the
value be
ing
w
ritten (var
iabl
e 99)
may
be a negative valu
e, among other reasons.
A59
IN/OU
T
comm
and port flag er
ror
w
a
rning
T
he number of I/O ports
(
flags
) may
hav
e ex
c
eeded 32,
among other reasons. Check
the I/O port (fla
g) specifications.
A5B
Char
acter-string
o
value conversion error
w
a
rni
ng
T
he specified number of conv
erting characters is invalid or
characters that
cannot be
converted to value are inc
luded.
A5C
Copy
ing-c
haracter count error
w
a
rn
ing
w
ith S
C
PY command
The specified number of copy
ing char
acters i
s
invali
d.
A5D
SCIF open err
or in non-AUT
O mode
T
he channel
w
a
s ope
ne
d in a
non-AUT
O mode. In the MANU mode, the P
C
/T
P
connection must be forcibl
y di
sconnected before op
eni
ng the serial c
hannel opened
to the user. Exercise caution.