Parameter utilization examples (reference) – IAI America SSEL User Manual
Page 417
395
Appendix
3. Parameter
Utilization
Examples
(Reference)
Description
Action
Parameter
settin
g
Operation/outco
me
1
Suppress genera
tion of erro
rs pert
aining
to the standard
I/
O boa
rd (so that
trial
operation can be
perform
ed befo
re the
board is
w
ired, fo
r exam
ple).
The I/
O-boa
rd e
rror monito
r can
be disabled to suppress erro
r
generation.
Set “0” in the I/
O
paramete
r corres
ponding
to the I/O
whose
error monitor is t
o be
disabled.
Standard I/
O: I/
O paramete
r No. 1
0 = 0
To disable the error monito
r of the
standard
I/O boa
rd, set “0
” in I/O parameter No. 10.
Note: Before ope
rating the I/
O bo
ard again,
be sure to reset the paramet
er value to “1.
”
2
Implement a rest
art (soft
w
a
re reset)
using an exte
rnal input signal.
A desired input p
o
rt can be set as
a restart input.
Set the follow
ing
value in the I/O p
aramete
r
“Input function se
lection n” corresp
onding to
the selected input port:
I/O pa
rameter “In
put function specification
value” = 3
The controller
w
ill
be restarted
wh
en the
specified port has remained ON f
o
r at least
1 second.
3
Turn on
the serv
o using an exte
rn
al input
signal.
A desired input p
o
rt can be set as
a servo ON input
.
Set the follow
ing
value in the I/O p
aramete
r
“Input function se
lection n” corresp
onding to
the selected input port:
I/O pa
rameter “In
put function specification
value” = 4
The servo
w
ill turn ON at
the
ON
edge of
the specified port.
The servo
w
ill turn OFF at the
OFF edge.
4
Start an auto
-sta
rt prog
ram using
an
external input signal. (Unde
r the d
efault
setting, the auto-start program
w
ill start
w
h
en the po
wer i
s
input or the con
troller
is restarted (b
y soft
w
are
reset) in
the
AUTO m
ode.)
(T
he steps to start t
he
auto-start program w
ill increase.)
A desired input p
o
rt can be set as
an input for aut
o-program
start
signal.
Set the follow
ing
value in the I/O p
aramete
r
“Input function se
lection n” corresp
onding to
the selected input port:
I/O pa
rameter “In
put function specification
value” = 5
Other
param
eter
No. 7 = 0
The pro
gram
w
ill start at the
ON e
dge of the
specified port.
The pro
gram
w
ill end at the
OFF e
dge.
5
Pause operation
s using an extern
al input
signal.
A desired input p
o
rt can be set as
a pause input.
A desired input p
o
rt can be set as
a pause reset inp
ut.
Set the follow
ing
value in each I/O
paramete
r “Inp
ut
function selectio
n n”
corresponding to
the selected input port:
I/O pa
rameter “In
put function specification
value” = 7
I/O pa
rameter “In
put function specification
value” = 8
Setting example) To set input port
No. 5 as
the pause reset i
nput and input p
ort No. 6
as the pause input, set “8” in I/
O
paramete
r
No. 35 and
“7” in
I/O pa
ramete
r N
o. 36.
Operations
w
ill pause at the OFF
edge of
the specified port set as the opera
tion-
pause signal input.
Pause w
ill be res
e
t at the
ON edge of the
port set as the o
peration-p
ause reset signal
input. (The
port s
et as the opera
tion-pause
signal input is alw
a
ys
ON.)
6
Reset erro
rs (errors of opera
tion-
cancellation leve
l or lo
w
e
r) using a
n
external input signal.
A desired input p
o
rt can be set as
an erro
r reset inp
ut.
Set the follow
ing
value in the I/O p
aramete
r
“Input function se
lection n” corresp
onding to
the selected input port:
I/O pa
rameter “In
put function specification
value” = 16
Errors
w
ill be res
e
t at the
ON edge of the
specified port.
7
Perform ho
me re
turn using an e
x
ternal
input signal.
A desired input p
o
rt can be set as
a home retu
rn in
put.
Set the follow
ing
value in the I/O p
aramete
r
“Input function se
lection n” corresp
onding to
the selected input port:
I/O pa
rameter “In
put function specification
value” = 18
Home return
w
ill be performed at the ON
edge of the speci
fied port. (The se
rvo must
be
turned ON first.)