beautypg.com

3 movements through positions – IAI America SSEL User Manual

Page 350

background image

328

Part 3 Positioner Mode

5.3 Movements

through

Positions

Timings of how the actuator moves through positions are illustrated below.

Timing Chart of Movement through Positions (Standard Positioner Mode)

T

1

: At least 6 msec

Operate the actuator to move through positions by following the procedure explained below.
* Confirm beforehand that the positioning complete output signal, home-return complete output signal

and servo-ON status output signal are all ON.
[1] Change the previous product/position number inputs to different product/position numbers.
[2] Turn ON the start input signal.
[3] Confirm that the positioning complete output signal is OFF.
[4] Turn OFF the start input signal.
[5] Confirm that the positioning complete output signal is ON.

Repeat steps [1] through [5] sequentially.

*Pause and *cancellation inputs are contact-B input signals (always ON), so keep these signals ON while
the actuator are moving through the specified positions.

Input

Output

Start

Home return

Product/
position input

Alarm

Ready

Positioning complete

Home return complete

Servo ON status