MDE-4315 CFN Series CFN III Manager’s Manual for Windows NT · August 2004

Page D-9

Appendix D: Status and Error Messages

No Tokheim Handler

Logged after the boot message if the system has at least one Tokheim pump defined in the
pump configuration, but no Tokheim handler. Tokheim handler is always assigned to port 3.

No Wayne Handler

Logged after the boot message if the system has at least one Wayne pump defined in the pump
configuration, but no Wayne handler is assigned to any serial port in the serial-port-
configuration section of the SYS_PAR configuration program (see MDE-4316 CFN III
Configuration Manual).

Assign an available serial port to the special pump handler using SYS_PAR.

NT PC-SCIII Interface V#.# Started

Boot message that the SC#.EXE interface program has started.

PC Not Responding

The site is running but not getting a response from the PC through the SC3.EXE program.
Check the PC. May see this on startup. Site should still open.

PC Responding

Site is communicating with the PC.

No action is necessary.

Product #XX Name Below Reorder Level

The product inventory of the indicated product is below the reorder level configured with the
LOAD INVENTORY command.

Follow your company’s procedures for reordering products.

Pump #X Disabled

The indicated pump has been disabled by the command DISABLE PUMP.

No action is required. Return the pump to operation with the command ENABLE PUMP when
appropriate.

Pump #X Disabled, No Quantity

The indicated pump has been disabled because the SC III has received too many zero-quantity
transactions from that pump.

A zero-quantity transaction is one in which the pump is activated but no fuel is pumped. The
SC III will automatically disable any pump that exceeds a certain number (set in SYS_PAR) of
zero-quantity transactions. This is a precaution against pump pulser (flow sensor) or pulser
cable failure.