Diagnostic Commands
Page 226
MDE-4315 CFN Series CFN III Manager’s Manual for Windows NT · August 2004
Errors in Site Controller-to-island card reader messages:
NB3 — buffer in use
NB4 — not hexadecimal
NB5 — invalid command
NB6 — undefined EE command number
NB7 — overflow/framing error
NB8 — input buffer overrun
NB9 — alphanumeric display busy
NBA — bad cyclical redundancy check (CRC)
Console Error Codes
Errors in console-to-Site Controller messages:
CRC — bad cyclical redundancy check (CRC)
DIE — device went down
NOR — no response
PIN — PIN errors
RDE — card read error
Errors in Site Controller-to-console messages:
NB3 — buffer busy
NB5 — invalid command
NB7 — receiver overrun
NBA — bad cyclical redundancy check (CRC)
Fuel Point Reader Error Codes
Errors in FPR-to-Site Controller messages:
CRC — bad cyclical redundancy check (CRC)
DIE — device went down
NOR — no response
PIN — PIN errors
Errors in Site Controller-to-FPR messages:
NB4 — not hexadecimal
NB5 — invalid command
NB7 — receiver overrun
NB8 — input buffer overrun
Event History
The CFN3 application remembers the last one hundred significant events. Events remembered
in history include:
• any command execution, except disk-based programs (which are files with the .BIN
extension).
• changes in switch detect on pumps.
• low level state changes for all transactions.
• other miscellaneous system events.
The event history is mainly useful for tracking down problems. Your service technician may
have you print out the history file if you call with a problem.