MDE-4315 CFN Series CFN III Manager’s Manual for Windows NT · August 2004

Page D-7

Appendix D: Status and Error Messages

EMERGENCY STOP

An emergency stop has been done from the console, or a STOP; a command
was issued.

No action is required. Press the EMERGENCY STOP key on the console again
when all is secure to end the emergency stop, or issue a RUN;A command from
the terminal keyboard.

End EMERGENCY STOP

Emergency stop done from the console is no longer in effect.

No action is required.

Fuel Point Reader # on Loop # Went Down

A Fuel Point Reader has gone down.

Check reader.

Fuel Point Reader # Came Up

A Fuel Point Reader has come back online.

No action is requried.

Gate # on Loop # Went Down

A Gate has gone down.

Check gate.

Gate # Came Up

A Gate has come back online.

No action is requried.

Island EMERGENCY STOP

The EMERGENCY STOP button on the island has been pressed, or a
communications problem has developed on the RS-422 loop to the island.

To end an island emergency stop, enter a RUN;A command from the terminal
keyboard, or press the EMERGENCY STOP key on the console twice.