Appendix A: SC III Ports and Switches

Jumper Settings

Page A-4

MDE-4315 CFN Series CFN III Manager’s Manual for Windows NT · August 2004

Jumper Settings

SC-Comm CPU Board Settings

SC-Comm Memory I/O Board Settings

Jumper

Description

Setting

K3

AC power fail sense

2-3 to enable
1-2 to disable *

K4

AC watch dog timer

1-2 to enable *

K5

SC-Comm CPU (testing only)

1-2 to reset

K6

RS-485 loop 1,

2-3 for 4 wire *
1-2 for 2 wire

K7

RS-485 loop 2,

2-3 for 4 wire
1-2 for 2 wire *

K8

Rx Clock from synchronous modem (DB-25-15)

1-2 to connect

K9

ETC output to synchronous modem (DB-25-24)

1-2 to connect

K10

Tx clock input from synchronous mocem (DB-25-17)

1-2 to connect

K11

EPROM type

2-3 for 27128 or 27256

K12

EPROM type

2-3 for 27128 or 27256

* = default

Jumper

Description

Setting

K1

Date/Time Clock Speed

1-2 for 4 wait state*
2-3 for 1 wait state

K2

Enable A19 to RAM

2-3 for 128Kx8*
1-2 for 512Kx8

K3

RAM size

2-3 for 128Kx8*
1-2 for 512Kx8

K4

External Battery

no connector = disabled*

K5

Tokheim Reset Output Port 2
Do not Install, not supported

1-2 for reset

* = default