Gasboy CFN III Mgnr's Mnl V3.4 User Manual
Page 203

MDE-4315 CFN Series CFN III Manager’s Manual for Windows NT · August 2004
Page 187
Variables for Use in Command Files
Making Your Own Commands
%E
Last error code from last command. A 00 means the command was completed
successfully, greater than 00 usually means the command failed. (Note that FIND uses
the error code in a special way.)
00 = completed
01 = transaction(s) in progress
02 = not found (does not exist)
03 = invalid data
04 = card is valid
05 = card is not valid
06 = device is out of service
07 = pump is in use
08 = pump is not on
09 = illegal command
10 = completed, failed
11 = file full
12 = command is protected
13 = site is stopped
14 = invalid option
15 = valid card, bit-mapped
16 = valid card, limited
17 = invalid card, bit-mapped
18 = invalid card, limited
19 = expecting NC, NW
20 = string too long
21 = print a heading before this record
22 =
some valid, some not
23 =
print a subtotal before this record
24 = no price
25 = cannot open file
26 = site not stopped
27 = cannot activate
%C
Where command is being executed from:
1 = local command port (command terminal)
2 = remote command port
3 = cron
4 = Check Point #1
5 = Check Point #2
6 = Check Point #3
7 = Check Point #4
8 = Profit Point #1
9 = Profit Point #2
10 = Profit Point #3
11 = Profit Point #4
%R
Site run level:
0 = running
1 = blocking new transactions
2 = stopped
3 = emergency stopped
4 = memory full
5 = crashed
%Fd
Returns the amount of free space on the specified drive (where d is the drive)
Name
Definition