Lookup Program

are entered with the LOAD PRICE command.
Message - the optional message displayed when the card is used.
Rejection code - 0=okay; any other number means the card will be rejected
when presented by the customer and Denied will be displayed on the
reader. This can be useful to temporarily block access when payment is
overdue.
PIN - the optional PIN for this account.
Require odometer - indicates whether the card user is required to enter the
odometer reading; the default is no. If an odometer reading is required, the
Enter odometer step in the Site Controller’s READER configuration
program must be set to optional. If an odometer reading is required and the
Ask for $ amount field is set to no, set the Digits in restriction code in
SYS_PAR to 1 or 2; if an odometer reading is required and the Ask for $
amount
field is set to yes, set the Digits in restriction code in SYS_PAR to
2.
Require manual # - indicates whether the card user is required to manually
enter a number, such as a vehicle number; the default is no. If a manual
number is required, the Enter auxiliary number step in the Site
Controller’s READER configuration program must be set to optional. If a
manual number is required and the Ask for $ amount field is set to no, set
the Digits in restriction code in SYS_PAR to 1 or 2; if a manual number is
required and the Ask for $ amount field is set to yes, set the Digits in
restriction code
in SYS_PAR to 2.
Require PIN - indicates whether the card user is required to enter a Personal
Identification Number; the default is no. If a PIN is required, the Enter PIN
step in the Site Controller’s READER configuration program must be set to
optional. If a PIN is required and the Ask for $ amount field is set to no, set
the Digits in restriction code in SYS_PAR to 1 or 2; if a PIN is required
and the Ask for $ amount field is set to yes, set the Digits in restriction
code
in SYS_PAR to 2.
Ask for $ amount - should the customer be asked to enter a dollar amount
for fuel to be purchased; the default is no. If the customer enters an amount,
the pump will stop once that amount has been pumped. The customer can
either enter an amount or press the FILL button. If a $ amount is required,
the Enter amount step in the Site Controller’s READER configuration
program must be set to optional. If a $ amount is required, set the Digits in
restriction code
in SYS_PAR to 2.

Records

The Lookup program stores its data in records. Each lookup number and lookup
type together require one record (more than one record can contain the same
lookup number, but in that case, each record will have a different lookup type).

All records have the same number of fields (18 at the time this manual was
written), but few, if any, records will have all fields filled in.

The records are stored in a file named LOOKUP.DTA.