Check pt/profit pt #x disabled, Check pt/profit pt #x went down, Data corrupted in table – Gasboy CFN III Mgnr's Mnl V3.4 User Manual
Page 284: Card: xxxxxxxxxx des not ready, Diagnostics table too small, Disk full

Appendix D: Status and Error Messages
Page D-6
MDE-4315 CFN Series CFN III Manager’s Manual for Windows NT · August 2004
Check PT/Profit Pt #X Disabled
The indicated console has been disabled by the command DISABLE
CONSOLE.
No action is required. Return the console to operation with the command
ENABLE CONSOLE if appropriate.
Check PT/Profit Pt #X Went Down
The indicated console is not functioning.
Try to return the console to operation with the command ENABLE CONSOLE.
If that does not work, check to make sure the console power cord is plugged in
and that the RS-422/485 data cable (small 4-wire modular connector) is
connected.
If the console still does not work, execute the command PRINT
DIAGNOSTICS 4 and report the results to your service representative.
Data Corrupted in Table
Data in table table has become corrupted. The SC III will reconstruct the table
and reboot itself in the crashed state.
See
“Name Table Reconstructed” on page D-1
.
CARD: XXXXXXXXXX DES Not Ready
DES (data encryption standard) encryption unit in a card reader was not ready to
process a bank card, probably because one of the two keys was not loaded.
Contact your bank network representative.
Diagnostics Table Too Small
Not enough available records in the diagnostic table.
The size of the diagnostic table is set in the SC III configuration.
If this message occurs at startup, you will need to configure for a larger
diagnostic table size.
Disk Full
The RAM disk is full.
Delete unnecessary files from the disk.