3.8 Service the Exit Transport Module
No additional service is necessary for the Exit Transport, other than the roller cleaning described in
section 3.3 Clean All Transport Rollers.
3.9 Cool the Tipper Heater / Power Down the Device
1) Navigate to
Menu
>
Settings
>
Tipper
to open the
Tipper
page.
2) Press the
Set Heater OFF
button to turn off the tipper heater.
3) Note the value under Current Tipper Temp. If the tipper temperature is 50°C or hotter, the tipper
heater is not safe to touch.
4) Take note of the current time, and plan your work to allow enough time for the tipper heater to cool,
which can take up to 15 minutes. You may be able to use compressed air to cool it more quickly.
5) Power down the device.