5 - Adjustments

ExpressCard 2000| Instant Issuance Card Personalization System | Hardware Service Manual


Page 150

4) Repeat the

Calibrate Wheel Home

operation several times until you see the same number three

times in a row. If the number continues to change after 10 tests, report the unit’s failure to calibrate.

5) Check that the value below

Calibrate Wheel Home

is between 4 and 10. If the value is not in that

range, report the unit’s failure to calibrate within the acceptable range.

6) After successfully calibrating, press the

Save

button to save the new embosser wheel center value.

7) Press the

OK

button to dismiss the popup window confirming it has been saved.

8) Open the top access door and inspect the embosser tine position to make sure the currently selected

tine is centered in the embosser bridge opening.

9) Press the

Status

button to return to the

Status

page.