AG-1029

8

AG-1029

Message

FC ports going to different fabrics. Disabling ports going to different fabric.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a misconfiguration.

Recommended

Action

Connect all ports in the switch to the same FC fabric.

AG-1030

Message

N-Port (ID: ) has been determined to be unreliable.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the port goes online and offline often and therefore the port is marked as unreliable.

Recommended

Action

No action is required. The port will automatically be marked as reliable after a certain interval of time if
the port toggling remains within the threshold limit.

AG-1031

Message

Loop Detected for device with Port WWN connected to port .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a routing loop is detected for the device connected to the specified port.

Recommended

Action

Check the device configuration.

AG-1032

Message

N-Port (ID: ) has recovered from an unreliable state.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the port state has been stable for the last five minutes.