beautypg.com

Eanv messages, Eanv-1001, Eanv-1002 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 164: Eanv-1003

background image

148

Network OS Message Reference

53-1003227-01

EANV-1001

8

EANV Messages

EANV-1001

Message

Port port fault. Change the SFP transceiver or check the cable.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.

Recommended

Action

Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.

EANV-1002

Message

Port chip faulted due to an internal error.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates an internal error. All the ports on this chip will be disabled.

Recommended

Action

Reload the system at the next maintenance window.

EANV-1003

Message

C: HW ASIC Chip error. Type = 0x, Error =

string>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

Reload the system at the next maintenance window.