beautypg.com

Nsm-1027, Nsm-1028, Nsm-1029 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 321

background image

Network OS Message Reference

305

53-1003227-01

NSM-1027

8

NSM-1027

Message

transceiver for interface is removed.

Message Type

DCE

Severity

INFO

Probable Cause

Indicates that a transceiver (SFP or CFP2) has been removed from the specified interface.

Recommended

Action

No action is required.

NSM-1028

Message

Incompatible SFP transceiver for interface is detected.

Message Type

DCE

Severity

ERROR

Probable Cause

Indicates that an incompatible small form-factor pluggable (SFP) transceiver for the interface has been
inserted.

Recommended

Action

Disable the interface using the shutdown command and insert an SFP transceiver that is supported on
the interface. After the SFP transceiver is inserted, re-enable the interface using the no shutdown
command.

NSM-1029

Message

Failed to read SFP transceiver for interface .

Message Type

DCE

Severity

ERROR

Probable Cause

Indicates failure to read the small form-factor pluggable (SFP) transceiver for the specified interface.

Recommended

Action

Disable the interface using the shutdown command and re-insert the SFP transceiver. After the SFP
transceiver is inserted, re-enable the interface using the no shutdown command. If the problem persists,
contact your switch service provider.