FW-1001
8
FW Messages
FW-1001
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the internal temperature of the switch has changed.
Recommended
Action
Respond to this message as is appropriate to the particular policy of the end-user installation. To prevent
recurring messages, disable the changed alarm for this threshold. If you receive a temperature-related
message, check for an accompanying fan-related message and check fan performance. If all fans are
functioning normally, check the climate control in your lab.
FW-1002
Message
is
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the internal temperature of the switch has fallen below the low boundary.
Recommended
Action
Respond to this message as is appropriate to the particular policy of the end-user installation. Typically,
low temperatures means that the fans and airflow of a switch are functioning normally.
Verify that the location temperature is within the operational range of the switch. Refer to the Hardware
Reference Manual for the environmental temperature range of your switch.
FW-1003
Message
is
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the internal temperature of the switch has risen above the high boundary to a value that
may damage the switch.
Recommended
Action
This message generally appears when a fan fails. If so, a fan-failure message accompanies this
message. Replace the fan.