beautypg.com

Fw messages, Fw-1001, Fw-1002 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 222: Fw-1003

background image

206

Network OS Message Reference

53-1003227-01

FW-1001

8

FW Messages

FW-1001

Message

.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the internal temperature of the switch has changed.

Recommended

Action

Respond to this message as is appropriate to the particular policy of the end-user installation. To prevent
recurring messages, disable the changed alarm for this threshold. If you receive a temperature-related
message, check for an accompanying fan-related message and check fan performance. If all fans are
functioning normally, check the climate control in your lab.

FW-1002

Message

is .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the internal temperature of the switch has fallen below the low boundary.

Recommended

Action

Respond to this message as is appropriate to the particular policy of the end-user installation. Typically,
low temperatures means that the fans and airflow of a switch are functioning normally.

Verify that the location temperature is within the operational range of the switch. Refer to the Hardware
Reference Manual
for the environmental temperature range of your switch.

FW-1003

Message

is .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the internal temperature of the switch has risen above the high boundary to a value that
may damage the switch.

Recommended

Action

This message generally appears when a fan fails. If so, a fan-failure message accompanies this
message. Replace the fan.