8

HASM-1132

Message

Reset the Ethernet PHY for slot (>) on

standby.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there was no Ethernet connection between the standby management module and the
specified line card (LC). The standby management module attempted to recover the connection by
resetting the PHY in the LC.

Recommended

Action

Execute the copy support command and contact your switch service provider.

HASM-1200

Message

Detected termination of process :

ID>.

Message Type

FFDC | LOG

Severity

WARNING

Probable Cause

Indicates that a process on the switch has ended unexpectedly.

Recommended

Action

Copy the warning message along with any core file information and contact your switch service provider.

HASM-1201

Message

: failed to refresh (

time>:, kill-).

Message Type

FFDC | LOG

Severity

WARNING

Probable Cause

Indicates that one of the daemons is found to be unresponsive. An abort signal is sent.

Recommended

Action