beautypg.com

Chs messages, Chs-1002, Chs-1003 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 139: Chs-1004

background image

Network OS Message Reference

123

53-1003227-01

CHS-1002

8

CHS Messages

CHS-1002

Message

ki_gd_register_action failed with rc = .

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates an internal error.

Recommended

Action

Reload or power cycle the switch.

CHS-1003

Message

Slot ENABLED but Not Ready during recovery, disabling slot = , rval =

.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the slot state has been detected as inconsistent during failover or recovery.

Recommended

Action

For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.

For a compact switch, reload or power cycle the switch.

CHS-1004

Message

Interface module attach failed during recovery, disabling slot = ,

rval = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified interface module has failed during failover or recovery.

Recommended

Action

For a modular switch, execute the power-off and power-on commands to power cycle the interface
module.

For a compact switch, reload or power cycle the switch.