SSMD-1004

8

SSMD-1004

Message

Failed to unlock semaphore mutex: ().

Message Type

DCE

Severity

ERROR

Probable Cause

Indicates that the specified function has failed to unlock the mutex (semaphore).

Recommended

Action

Reload or power cycle the switch.

SSMD-1005

Message

SSM startup failed.

Message Type

DCE

Severity

ERROR

Probable Cause

Indicates that the Data Center Ethernet (DCE) System Services Manager (SSM) has encountered an
unexpected severe error during basic startup and initialization.

Recommended

Action

Reload or power cycle the switch.

If the problem persists, download a new firmware version using the firmware download command.

SSMD-1006

Message

SSM ASIC downlaod buffer overflow (size > max

size>) in function .

Message Type

DCE

Severity

ERROR

Probable Cause

Indicates that the Data Center Ethernet (DCE) System Services Manager (SSM) has encountered an
unexpected severe error when fill in the I/O control (IOCTL) structure.

Recommended

Action

Reload or power cycle the switch.

If the problem persists, download a new firmware version using the firmware download command.