Hil-1521, Hil-1522, Hil-1523 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 266

background image

250

Network OS Message Reference

53-1003227-01

HIL-1521

8

HIL-1521

Message

, high temperature ().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the temperature of the specified interface module has risen above the warning threshold.

Recommended

Action

Execute the show environment fan command to verify that all fans are working properly.

Make sure that the area is well ventilated and that the room temperature is within operational range of
your switch. Refer to the Hardware Reference Manual of your switch for the operational temperature
range.

HIL-1522

Message

, high temperature (). Unit will be shut

down in 2 minutes if temperature remains high.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the temperature of the specified interface module has risen above the critical threshold.
This usually follows a high temperature message.

Recommended

Action

Execute the show environment fan command to verify that all fans are working properly.

Make sure that the area is well ventilated and the room temperature is within operational range of your
switch. Refer to the Hardware Reference Manual of your switch for the operational temperature range.

If the message persists, replace the interface module.

HIL-1523

Message

, unit shutting down.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the temperature of the specified interface module was above the maximum threshold for at
least two minutes and therefore it has been shut down to prevent damage. This message usually follows
a high temperature warning message.

Recommended

Action

Execute the show environment fan command to verify that all fans are working properly.

Make sure that the area is well ventilated and the room temperature is within the operational range of
your switch. Refer to the Hardware Reference Manual of your switch for the operational temperature
range.

If the message persists, replace the faulty interface module.