Bl messages, Bl-1000, Bl-1001 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 117: Bl-1002
Network OS Message Reference
101
53-1003227-01
BL-1000
8
BL Messages
BL-1000
Message
Initializing ports...
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the switch has started initializing the ports.
Recommended
Action
No action is required.
BL-1001
Message
Port initialization completed.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the switch has completed initializing the ports.
Recommended
Action
No action is required.
BL-1002
Message
Init Failed: of internal port number not ONLINE>. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that the interface module initiation failed because one or more of the internal ports were not Recommended Action Make sure that the interface module is seated correctly. If the interface module is seated correctly, reload Execute the diag systemverification command to verify that the interface module does not have Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled. Additional interface module fault messages precede and follow this error, providing more information. If the message persists, replace the interface module.
online. The interface module is faulted.
or power cycle the interface module using the power-off and power-on commands.
hardware problems.
Refer to other error messages for the recommended action.