Network OS Message Reference

103

53-1003227-01

BL-1007

8

Recommended

Action

Execute the show ha command to verify that the standby management module is healthy. If the problem
persists, remove and reinstall the faulty interface module.

If the standby management module was removed or faulted by user intervention, no action is required.

BL-1007

Message

interface module #: state is inconsistent with EM.

bl_cflags 0x, slot_on , slot_off

, faulty , status .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a failover occurred while an interface module was initializing on the previously active
management module.

Recommended

Action

No action is required. The interface module is re-initialized. Because re-initializing an interface module is
a disruptive operation and can stop I/O traffic, you must stop and restart the traffic during this process.

BL-1008

Message

control-plane failure. Expected value: 0x, Actual: 0x

2>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the interface module has experienced a hardware failure or was removed without following
the recommended removal procedure.

Recommended

Action

Make sure that the interface module is seated correctly. If the interface module is seated correctly, reload
or power cycle the interface module using the power-off and power-on commands.

Execute the diag systemverification command to verify that the interface module does not have
hardware problems.

Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled.

If the message persists, replace the interface module.

BL-1009

Message

Interface module in slot timed out initializing the chips.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the interface module has failed to initialize the application-specific integrated circuit (ASIC)
chips.