Bl-1007, Bl-1008, Bl-1009 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 119

Network OS Message Reference
103
53-1003227-01
BL-1007
8
Recommended
Action
Execute the show ha command to verify that the standby management module is healthy. If the problem
persists, remove and reinstall the faulty interface module.
If the standby management module was removed or faulted by user intervention, no action is required.
BL-1007
Message
interface module #
bl_cflags 0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a failover occurred while an interface module was initializing on the previously active
management module.
Recommended
Action
No action is required. The interface module is re-initialized. Because re-initializing an interface module is
a disruptive operation and can stop I/O traffic, you must stop and restart the traffic during this process.
BL-1008
Message
2>. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that the interface module has experienced a hardware failure or was removed without following Recommended Action Make sure that the interface module is seated correctly. If the interface module is seated correctly, reload Execute the diag systemverification command to verify that the interface module does not have Execute the diag post command to make sure that Power-On Self-Test (POST) is enabled. If the message persists, replace the interface module. BL-1009 Message Interface module in slot Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that the interface module has failed to initialize the application-specific integrated circuit (ASIC)
the recommended removal procedure.
or power cycle the interface module using the power-off and power-on commands.
hardware problems.
chips.