beautypg.com

C3-1017, C3-1019, C3-1020 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 137

background image

Network OS Message Reference

121

53-1003227-01

C3-1017

8

C3-1017

Message

Interface module in Slot- failed due to unavailability of ports in

the internal trunk.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified interface module failed due to unavailability of ports in the internal trunk.

Recommended

Action

Whenever this error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, replace the interface module.

C3-1019

Message

,C: HW ASIC Chip TXQ FID parity error threshold reached

type = 0x.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

Reload the system at the next maintenance window.

C3-1020

Message

,P(): Some non-critical

CRC with good EOF errors were observed: current:0x,

last:0x, thresh1:0x.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that some non-critical errors were detected in the hardware.

Recommended

Action

No action is required.