Network OS Message Reference

53-1003227-01

EM-1004

8

EM-1004

Message

failed to power on.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the specified field-replaceable unit (FRU) failed to power on and is not being used. The
FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port.

Recommended

Action

Reseat the FRU. If the problem persists, replace the FRU.

EM-1005

Message

has faulted. Sensor(s) above maximum limits.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that an interface module in the specified slot or the switch (for compact switches) is being shut
down for environmental reasons; its temperature or voltage is out of range.

Recommended

Action

Check the environment and make sure the room temperature is within the operational range of the
switch. Execute the show environment fan command to verify fans are operating properly. Make sure
there are no blockages of the airflow around the chassis. If the temperature problem is isolated to the
interface module itself, replace the interface module.

Voltage problems on a interface module are likely a hardware problem on the interface module itself;
replace the interface module.

EM-1006

Message

has faulted. Sensor(s) below minimum limits.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the sensors show the voltage is below minimum limits. The switch or specified interface
module is being shut down for environmental reasons; the voltage is too low.

Recommended

Action

If this problem occurs on an interface module, it usually indicates a hardware problem on the interface
module; replace the interface module.

If this problem occurs on a switch, it usually indicates a hardware problem on the main board; replace the
switch.