Viewing and clearing the RASLog messages
1
Displaying the RASLog messages
To display the saved RASLog messages, perform the following steps.
1. Log in to the switch as admin.
2. Enter the show logging raslog command at the command line.
switch# show logging raslog
NOS: v4.1.1
2012/06/04-22:57:00, [HASM-1108], 94,, INFO, VDX6720-24, All service instances
become active.
2012/06/04-22:57:03, [DCM-1002], 96,, INFO, VDX6720-24, PostBoot processing on
global config has started.
2012/06/04-22:57:05, [BL-1000], 100,, INFO, VDX6720-24, Initializing ports...
2012/06/13-05:10:22, [NSM-1004], 4428, DCE, INFO, sw0, Interface Vlan 1 is
created.
2012/06/13-05:10:24, [DOT1-1013], 4435, DCE, INFO, sw0, DOT1X test timeout
value is set to 10.
2012/06/13-05:10:24, [ONMD-1002], 4437, DCE, INFO, sw0, LLDP global
configuration is changed.
2012/06/13-05:10:28, [RAS-2001], 4438,, INFO, sw0, Audit message log is
enabled.
[...]
Displaying the messages on an interface module
To display the saved messages for a specific interface module, line card (LC), or management
module, perform the following steps.
1. Log in to the switch as admin.
2. Enter the show logging raslog blade command at the command line. You can filter messages
based on the severity level using the severity option. The following example filters messages by
the severity level of info.
switch# show logging raslog blade LC2 severity info
NOS: v4.1.1
2012/05/29-11:43:06, [HASM-1004], 6919, L2, INFO, VDX8770-4, Processor
rebooted - Reset.
2012/05/29-11:43:06, [HASM-1104], 6920, L2, INFO, VDX8770-4, Heartbeat to M2
up.
2012/05/29-11:43:10, [HASM-1004], 6921, L2, INFO, VDX8770-4, Processor
rebooted - Reset.
2012/05/29-11:43:10, [HASM-1104], 6922, L2, INFO, VDX8770-4, Heartbeat to M2
up.
[...]