Plat-1007, Plat-1008, Plat-1009 – Brocade Network OS Message Reference v4.1.1 User Manual
Page 357

Network OS Message Reference
341
53-1003227-01
PLAT-1007
8
PLAT-1007
Message
Turning off Fan direction>. Message Type LOG Severity ERROR Probable Cause Indicates that the specified fan is turned off because of an incorrect airflow direction. Recommended Action Replace the fan field-replaceable units (FRUs) in such a manner that the air flows in the same direction, PLAT-1008 Message Unable to read EEPROM for Global airflow direction. Message Type LOG Severity ERROR Probable Cause Indicates a failure to read the electrically erasable programmable read-only memory (EEPROM) and Recommended Action Execute the copy support command and contact your switch service provider. PLAT-1009 Message Unable to read EEPROM Valid Signature for Global airflow direction. Message Type LOG Severity ERROR Probable Cause Indicates that the content read from electrically erasable programmable read-only memory (EEPROM) is Recommended Action Execute the copy support command and contact your switch service provider.
that is, towards the port side or away from the port side of the system. Refer to the Hardware Reference
Manual of your switch for instructions to replace the fan FRU.
therefore unable to determine the global airflow direction of the fans.
invalid and therefore unable to determine the global airflow direction of the fans.