beautypg.com

Hil messages, Hil-1202, Hil-1301 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 263: Hil-1302

background image

Network OS Message Reference

247

53-1003227-01

HIL-1202

8

HIL Messages

HIL-1202

Message

Blower faulted, speed ( RPM) below threshold.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold.

Recommended

Action

Replace the fan field-replaceable unit (FRU). Refer to the Hardware Reference Manual of your switch for
instructions to replace the fan FRU.

HIL-1301

Message

A blower failed or missing. Replace failed or missing blower assembly immediately.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is often
preceded by a low speed error message. This problem may overheat the switch.

Recommended

Action

Replace the affected fan FRU immediately. Refer to the Hardware Reference Manual of your switch for
instructions to replace the fan FRU.

HIL-1302

Message

blowers failed or missing. Replace failed or missing blower assemblies

immediately.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that multiple fan field-replaceable units (FRUs) have failed or are missing on the switch. This
message is often preceded by a low fan speed message.

Recommended

Action

Replace the affected fan FRUs immediately. Refer to the Hardware Reference Manual of your switch for
instructions to replace the fan FRU.