beautypg.com

Em-1037, Em-1042, Em-1043 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 176

background image

160

Network OS Message Reference

53-1003227-01

EM-1037

8

Recommended

Action

Reseat the FRU card.

If the problem persists, reload or power cycle the switch.

Execute the diag systemverification command to verify that the switch does not have hardware
problems.

If the problem still persists, replace the FRU.

EM-1037

Message

is no longer faulted.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified power supply is no longer marked faulty; probably because its AC power
supply has been turned on.

Recommended

Action

No action is required.

EM-1042

Message

Important FRU header data for is invalid.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU
header-derived information. This could mean that the FRU header was corrupted or read incorrectly, or it
is corrupted in the object database, which contains information about all the FRUs.

Recommended

Action

Reseat the FRU. If the problem persists, replace the FRU.

EM-1043

Message

Cannot power .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified field-replaceable unit (FRU) could not be powered on or off. The FRU is not
responding to commands.

Recommended

Action

Reseat or replace the FRU.