FSPF-1005
8
FSPF-1005
Message
Wrong Section Id number>. Message Type LOG Severity ERROR Probable Cause Indicates that an incorrect section ID was reported from the specified input port. The section ID is part of Recommended Action This switch does not support a non-zero section ID. Any connected switch from another manufacturer FSPF-1006 Message FSPF Version Message Type LOG Severity ERROR Probable Cause Indicates that the fabric shortest path first (FSPF) version is not supported on the specified input port. Recommended Action Update the FSPF version by running the firmware download command. All current versions of the FSPF-1007 Message ICL triangular topology is broken between the neighboring RBridges: number> and Message Type LOG Severity ERROR Probable Cause Indicates that the inter-chassis link (ICL) triangular topology is broken and becomes linear. It may cause Recommended Action Investigate the ICLs and reconnect the switches to form a triangular topology.
the fabric shortest path first (FSPF) protocol and is used to identify a set of switches that share an
identical topology database.
with a section ID other than 0 is incompatible in a fabric of Brocade switches. Disconnect the
incompatible switch.
Network OS support FSPF version 2.
frame drop or performance slowdown.