FSPF-1005

8

FSPF-1005

Message

Wrong Section Id

, should be
, input port =

number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an incorrect section ID was reported from the specified input port. The section ID is part of
the fabric shortest path first (FSPF) protocol and is used to identify a set of switches that share an
identical topology database.

Recommended

Action

This switch does not support a non-zero section ID. Any connected switch from another manufacturer
with a section ID other than 0 is incompatible in a fabric of Brocade switches. Disconnect the
incompatible switch.

FSPF-1006

Message

FSPF Version not supported, input port = .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the fabric shortest path first (FSPF) version is not supported on the specified input port.

Recommended

Action

Update the FSPF version by running the firmware download command. All current versions of the
Network OS support FSPF version 2.

FSPF-1007

Message

ICL triangular topology is broken between the neighboring RBridges:

number> and . Please fix it ASAP.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the inter-chassis link (ICL) triangular topology is broken and becomes linear. It may cause
frame drop or performance slowdown.

Recommended

Action

Investigate the ICLs and reconnect the switches to form a triangular topology.