BL-1026

8

BL-1026

Message

Internal port offline during warm recovery, state (0x).

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that an internal port went offline during warm recovery of the switch. The switch will reboot and
start a cold recovery.

Recommended

Action

Execute the copy support command and reload the switch.

Execute the diag post command to make sure Power-On Self-Test (POST) is enabled.

If the problem persists, replace the switch.

BL-1027

Message

Interface module in faulted, boot failed; status 0x

0x<1250 0 boot status> 0x<1250 1 boot status>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the interface module failed to boot properly.

Recommended

Action

Reload or power cycle the interface module using the power-off and power-on commands. If the
message persists, replace the interface module.

BL-1028

Message

Switch faulted; internal processor was reset before switch init completed.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the switch internal processor was reset before the initialization completed.

Recommended

Action

Reload or power cycle the switch. If the message persists, replace the switch.