beautypg.com

Snmp messages, Snmp-1001, Snmp-1002 – Brocade Network OS Message Reference v4.1.1 User Manual

Page 412: Snmp-1003

background image

396

Network OS Message Reference

53-1003227-01

SNMP-1001

8

SNMP Messages

SNMP-1001

Message

SNMP service is not available .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Simple Network Management Protocol (SNMP) service could not be started because of
the specified reason. You will not be able to query the switch through SNMP.

Recommended

Action

Verify that the IP address for the Ethernet and Fibre Channel interface is set correctly using the show
interface management
command. If the specified reason is an initialization failure, reload the switch.

SNMP-1002

Message

SNMP initialization failed.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the initialization of the Simple Network Management Protocol (SNMP) service failed and
you will not be able to query the switch through SNMP.

Recommended

Action

Reload or power cycle the switch. This will automatically initialize SNMP.

SNMP-1003

Message

Distribution of Community Strings to Secure Fabric failed.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the changes in the Simple Network Management Protocol (SNMP) community strings
could not be propagated to other switches in the secure fabric.

Recommended

Action

Retry changing the SNMP community strings on the primary switch using the snmp-server community
command.